TM 5-3610-259-14
T a b l e 1 - 1.
OPERATOR S PREVENTIVE
B - Before
W - Weekly
D - During
M - Monthly
A
lTEM
NO.
2
3
4
After
IN-
TER
VAL
Q - Quarterly
MAINTENANCE CHECKS AND SERVICES (Cent)
AN - Annually
(Number) - Hundreds of
S
- Semiannually
BI - Biennially
ITEM TO BE INSPECTED
PROCEDURE
VAN BODY
INSPECT INTERIOR (Cont).
Grasp new wick with tweezers, and slip wick over
wet bulb thermometer.
Fill cistern with clean, fresh water.
Insert other end of wick into cistern.
Use eyedropper to saturate wick.
Mount psychrometer on wall.
INSPECT AIR CONDITIONER/HEATER. Refer to TM 5-4120-
367-14 for preventive maintenance checks and services
that pertain to air conditioners/heaters.
Servic Power Cable.
WARNING
Electrical shock hazard.
Power cable must be de-energized before servicing.
Death or serious injury may occur from failure tc ob-
serve this safety precaution.
Turn off safety switch.
Disconnect cable from power entry panel.
Wrap any cuts or abrasions in cable with electrical
insulation tape.
Reconnect power cable to entry panel.
Hours
For Readiness
Reporting,
Equipment Is
Not Ready/
Available If:
1.2.3 OPERATION UNDER USUAL CONDITIONS.
Operation of the Plate Process Section
consists of activation of power after the Section has been located at the operation
site and 12 vdc power disconnected.
TM 5-2330-305-14 provides detailed instructions
for disconnection of trailer chassis from tractor.
1-28