TM 5-3610-259-14
Repairer
2-16.21 Flush Vacuum Pump(s).
MOS: 83FJ6, Reproduction Equipment
TOOLS:
Tool Kit, Light Machine Repair
Flat Tip Screwdriver
Hex Head Key Wrench Set
Tool Kit,
Permanent
SUPPLIES:
Precision
Magnet
Nonflammable Flush
Rubber Matting
ing Solvent (Item , Appendix E)
Electrical shock hazard.
You must stand on rubber matting while performing
this procedure.
Death or serious injury may occur.
Always wear eye/face protective equipment when using solvent to prevent injury
to eyes.
Fumes and chemicals used in flushing vacuum pump may result in serious injury
if personnel do not operate equipment with proper ventilation.
a.
Turn off power panel circuit breaker.
b. Remove two screws and lower cabinet panel.
2-94