ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FLIP-TOP PLATEMAKER DOES NOT ENERGIZE.
Step 1.
Check for 220 V ac input to flip-top platemaker at utility outlet
box .
(a) If voltage is present, proceed to step 2.
(b) If no voltage is present, proceed to organizational trouble-
shooting in chapter 1.
Step 2.
Check for 220 V ac between fuses F1 and F2 on relay panel.
NOTE
It will be necessary to override lower cabinet door proximity switch
before voltage readings can be obtained. Remove magnet from door,
and place it on switch.
(a) If voltage is present, proceed to step 3.
(b) If voltage is not present, proceed to step 4.
Step 3.
Check output of master circuit breaker in platemaker.
(a) If voltage is present, replace master power switch (paragraph
2-16.12)
(b) If voltage is not present, replace master circuit breaker
(paragraph 2-16.16).