TM 5-3610-257-14
Table 1-5. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
NO POWER TO EQUIPMENT - Cont
Step 2.
Check circuit breaker input for 120 V ac.
(a)
If input voltage is present, proceed to step 3.
(b)
If input voltage is not present, refer to direct/general support maintenance for repair or replacement of
defective wiring.
Step 3.
Check circuit breaker output for 120 V ac.
(a)
If output voltage is present, proceed to step 4.
(b)
If output voltage is not present, refer to direct/general support maintenance for circuit breaker
replacement (paragraph 1-20.5).
Step 4.
Remove receptacle and check for 120 V ac input.
(a)
If present, replace receptacle (paragraph 1-16.6).
(b)
If not present, repair or replace defective wiring.
1-70