TM 5-3610-257-14
The water is heated by an immersion heater. When the IMMERSION HEATER lighted switch is closed, 208 V ac, 60 Hz is
applied to the immersion heater through a magnetic contactor and IMMERSION HEATER SWITCH S10. S10 has a lamp
in its circuit that will remain on until the water temperature reaches 700 F (210 C). The water temperature can be
monitored by the remote reading thermometer. The thermometer has a temperature range of O0F - 2580 F (-17.70C -
125.50C). The amount of water in the water storage tank is monitored by the water level gage. The water level gage uses
a float assembly in the water storage tank assembly to monitor the water level.
Draining the water storage tank is accomplished by opening all gate valves and removing the water drain cap on the water
drain.
Section II. OPERATING INSTRUCTIONS
1-4.
DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS.
Controls or Indicators
Function
Level Indicators
Indicate when section is level.
1-12