TM 5-3610-257-14
WARNING
Death or serious injury may occur from electrical shock unless darkroom in use circuit breaker is
turned off before servicing.
a.
Turn off circuit breaker.
b.
Remove darkroom in use indicator light assembly and power cord.
c.
Remove light integrating exposure control instrument remote station cord.
d.
Remove door assemblies.
e.
Remove screws securing camera to post assemblies.
f.
Remove rivets and defective darkroom partition assembly.
g.
Install new darkroom partition assembly.
h.
Install screws securing camera to post assemblies.
i.
Install door assemblies.
j.
Install light integrating exposure control instrument remote station cord.
k.
Install darkroom in use indicator light assembly and power cord.
l.
Test for light leaks. Repair any leaks with silicone sealant.
1-111