CHAPTER 1 CAMERA SECTIONHand Receipt (-HR) Manual.Location and Description of Major Components - TM-5-3610-257-14_10Location and Description of Major Components - cont - TM-5-3610-257-14_11Location and Description of Major Components - cont - TM-5-3610-257-14_12Location and Description of Major Components - cont - TM-5-3610-257-14_13Location and Description of Major Components - cont - TM-5-3610-257-14_14Equipment Data - ISO Container (Unmounted) - TM-5-3610-257-14_15Equipment Data - ISO Container and ChassisTECHNICAL PRINCIPLES OF OPERATION - TM-5-3610-257-14_17Water System and Drain SystemSection II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_19DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS - TM-5-3610-257-14_20DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS - cont - TM-5-3610-257-14_21DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS - cont - TM-5-3610-257-14_22DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS - cont - TM-5-3610-257-14_23PMCS Procedures - TM-5-3610-257-14_24PMCS Procedures - cont Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_26Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_27Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_28Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_29Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_30Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_31Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_32Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_33Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_34Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_35Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICESOPERATION UNDER USUAL CONDITIONSPreparation for Use - TM-5-3610-257-14_38Preparation for Use - cont - TM-5-3610-257-14_39Preparation for Use - cont - TM-5-3610-257-14_40Preparation for Use - cont - TM-5-3610-257-14_41Preparation for Use - cont - TM-5-3610-257-14_42Preparation for Use - cont - TM-5-3610-257-14_43Preparation for Use - cont - TM-5-3610-257-14_44Preparation for Use - cont - TM-5-3610-257-14_45Preparation for Use - cont - TM-5-3610-257-14_46Table 1-2. RELATIVE HUMIDITY, PERCENT - FAHRENHEIT TEMPERATURESTable 1-2. RELATIVE HUMIDITY, PER CENT - FAHRENHEIT TEMPERATURES - Cont - TM-5-3610-257-14_48Preparation for Use - cont - TM-5-3610-257-14_49Preparation for Use - cont - TM-5-3610-257-14_50Preparation for Use - cont - TM-5-3610-257-14_51Preparation for Movement - TM-5-3610-257-14_52Preparation for Movement - cont - TM-5-3610-257-14_53Preparation for Movement - cont - TM-5-3610-257-14_54Operating Instructions on Decals and Instruction Plates - TM-5-3610-257-14_55Operating Instructions on Decals and Instruction Plates - cont - TM-5-3610-257-14_56Operating Instructions on Decals and Instruction Plates - cont - TM-5-3610-257-14_57Operating Instructions on Decals and Instruction Plates - cont - TM-5-3610-257-14_58Operating Instructions on Decals and Instruction Plates - cont - TM-5-3610-257-14_59OPERATION UNDER UNUSUAL CONDITIONS - TM-5-3610-257-14_60Operation in Cold WeatherEmergency Means of Exit - TM-5-3610-257-14_62Table 1-3. TROUBLESHOOTINGTable 1-3. TROUBLESHOOTING - Cont - TM-5-3610-257-14_64Table 1-3. TROUBLESHOOTING - Cont - TM-5-3610-257-14_65MAINTENANCE PROCEDURES. - TM-5-3610-257-14_66Replace Fluorescent Tube in Ceiling LightService Air Conditioning Duct.Replace Battle Lamp/Dome Light.Section IV. ORGANIZATIONAL MAINTENANCE - TM-5-3610-257-14_70ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_71Table 1-4. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICESTable 1-4. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_73Table 1-4. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_74ORGANIZATIONAL TROUBLESHOOTING PROCEDURES - TM-5-3610-257-14_75Table 1-5. ORGANIZATIONAL TROUBLESHOOTING Table 1-5. ORGANIZATIONAL TROUBLESHOOTING - ContMAINTENANCE PROCEDURES - TM-5-3610-257-14_78Replace Fluorescent Light Ballast.Replace Fluorescent Light Ballast. - cont Replace Radio Frequency (RF) Filter Transformer.Replace Radio Frequency (RF) Filter Transformer. - cont Replace Fluorescent Light Switch - TM-5-3610-257-14_83Replace Fluorescent Light Switch - cont Replace On/Off Switch. - TM-5-3610-257-14_85Replace On/Off Switch. - cont Replace Battle Lamp/Dome Light MicroswitchReplace Receptacle - TM-5-3610-257-14_88Replace Receptacle - cont - TM-5-3610-257-14_89Replace Wire Raceway CoverReplace Wire Raceway Cover - cont Replace Emergency Light.Repair Blackout Curtain - TM-5-3610-257-14_93Repair Van Body Skin (Temporary) - TM-5-3610-257-14_94Repair Van Body Skin (Temporary) - cont - TM-5-3610-257-14_95Replace Level Indicator - TM-5-3610-257-14_96Replace Level Indicator - cont - TM-5-3610-257-14_97Replace Make Up Air Vent Screen,Replace Make UD Air Vent Outer DoorRepair Personnel Ladder. - TM-5-3610-257-14_100Repair Personnel Ladder. - cont PREPARATION FOR STORAGE OR SHIPMENT - TM-5-3610-257-14_102DIRECT/GENERAL SUPPORT TROUBLESHOOTING PROCEDURES - TM-5-3610-257-14_103Table 1-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING Table 1-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - ContMAINTENANCE PROCEDURES - TM-5-3610-257-14_106Repair Personnel Door Handle - TM-5-3610-257-14_107Repair Personnel Door Handle - cont - TM-5-3610-257-14_108Replace Cargo Door Latch Assembly. - TM-5-3610-257-14_109Replace Personnel/Cargo Door Gasket - TM-5-3610-257-14_110Replace Personnel/Cargo Doors - TM-5-3610-257-14_111Replace Personnel/Cargo Doors - cont - TM-5-3610-257-14_112Replace Circuit Breaker - TM-5-3610-257-14_113Repair Floor Covering - TM-5-3610-257-14_114Repair Van Body Skin (Permanent). - TM-5-3610-257-14_115Repair Van Body Skin (Permanent). - cont - TM-5-3610-257-14_116Replace Darkroom Partition Assembly.Replace Darkroom Partition Assembly. - cont Replace Darkroom Door GasketReplace Darkroom Door Assembly Threshold Seal.Replace Darkroom In Use Indicator Light AssemblyReplace Air Conditioner.Replace Air Conditioner. - cont Replace Air Conditioner Support Bracket - TM-5-3610-257-14_124Replace Air Conditioning Duct.Replace Air Conditioning Duct. - cont CHAPTER 2 LITHOGRAPHIC COPYING CAMERAReference Information - TM-5-3610-257-14_128CHAPTER 3 LIGHT INTEGRATING EXPOSURE CONTROL INSTRUMENTLocation and Description of Major Components. - TM-5-3610-257-14_130Equipment Data - TM-5-3610-257-14_131TECHNICAL PRINCIPLES OF OPERATION - TM-5-3610-257-14_132Time unit dialsFlash dialMulticolor phototube.Section II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_136DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS - cont - TM-5-3610-257-14_137DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS - cont - TM-5-3610-257-14_138OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES. - TM-5-3610-257-14_139PMCS Procedures. - TM-5-3610-257-14_140Table 3-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_141Table 3-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_142Assembly and Preparation for Use - TM-5-3610-257-14_143Assembly and Preparation for Use - cont - TM-5-3610-257-14_144Initial Adjustments, Daily Checks, and Self-Test - TM-5-3610-257-14_145Initial Adjustments, Daily Checks, and Self-Test - cont - TM-5-3610-257-14_146Initial Adjustments, Daily Checks, and Self-Test - cont - TM-5-3610-257-14_147Initial Adjustments, Daily Checks, and Self-Test - cont - TM-5-3610-257-14_148Initial Adjustments, Daily Checks, and Self-Test - cont - TM-5-3610-257-14_149Initial Adjustments, Daily Checks, and Self-Test - cont - TM-5-3610-257-14_150Initial Adjustments, Daily Checks, and Self-Test - cont - TM-5-3610-257-14_151Initial Adjustments, Daily Checks, and Self-Test - cont - TM-5-3610-257-14_152Operating Procedures - TM-5-3610-257-14_153Table 3-2. CONTROL SWITCH POSITIONSOperating Procedures - cont - TM-5-3610-257-14_155Table 3-3. DENSITY DIAL SETTINGSOperating Procedures - cont - TM-5-3610-257-14_157Table 3-4. FILTER FACTOR RATIO TO DENSITYTable 3-4. FILTER FACTOR RATIO TO DENSITY - ContOperating Procedures - cont - TM-5-3610-257-14_160Operating Procedures - cont - TM-5-3610-257-14_161EXPOSURE RECORDDENSITY AND TIME UNITS COMPENSATION TABLEOperating Procedures - cont - TM-5-3610-257-14_164Operating Procedures - cont - TM-5-3610-257-14_165Operating Procedures - cont - TM-5-3610-257-14_166Operating Procedures - cont - TM-5-3610-257-14_167Operating Procedures - cont - TM-5-3610-257-14_168Halftone exposure systemHalftone exposure system - cont - TM-5-3610-257-14_170Halftone exposure system - cont - TM-5-3610-257-14_171Halftone exposure system - cont Short range copy (very flat copy)Halftone exposure system (gray screen).Halftone exposure system (gray screen). - cont Halftone exposure system (gray screen). - cont - TM-5-3610-257-14_176Halftone exposure system (gray screen). - cont - TM-5-3610-257-14_177OPERATION UNDER UNUSUAL CONDITIONS - TM-5-3610-257-14_178Table 3-5. TROUBLESHOOTINGTable 3-5. TROUBLESHOOTING - Cont - TM-5-3610-257-14_180Table 3-5. TROUBLESHOOTING - Cont - TM-5-3610-257-14_181Table 3-5. TROUBLESHOOTING - Cont - TM-5-3610-257-14_182Section IV. ORGANIZATIONAL MAINTENANCE - TM-5-3610-257-14_183Section V. DIRECT/GENERAL SUPPORT MAINTENANCE - TM-5-3610-257-14_184Table 3-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont - TM-5-3610-257-14_185Table 3-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont - TM-5-3610-257-14_186MAINTENANCE PROCEDURES. - TM-5-3610-257-14_187Replace Internal LampCheck/Replace 2D21 and/or OB2 Tube(s)Check/Replace 2D21 and/or OB2 Tube(s) - contReplace Plug-In Relay (Rear Section)Replace Plug-In Relay (Rear Section) - cont Replace Plug-In Relay(s) (Front Section).Replace Plug-In Relay(s) (Front Section). - cont - TM-5-3610-257-14_194Replace Plug-In Relay(s) (Front Section). - cont - TM-5-3610-257-14_195Replace Plug-In Relay(s) (Front Section). - cont - TM-5-3610-257-14_196Replace Plug-In Relay(s) (Front Section). - cont - TM-5-3610-257-14_197Replace Cancel RelayReplace Cancel Relay - cont Replace Power Cord - TM-5-3610-257-14_200Replace Power Cord - cont - TM-5-3610-257-14_201Replace Power Cord - cont - TM-5-3610-257-14_202Replace Power Cord - cont - TM-5-3610-257-14_203Replace Multicolor Phototube Bulb(s)Replace Multicolor Phototube Bulb(s) - cont - TM-5-3610-257-14_205Replace Multicolor Phototube Bulb(s) - cont - TM-5-3610-257-14_206Replace Light Integrating Exposure Control Instrument.Replace Light Integrating Exposure Control Instrument. - cont CHAPTER 4 DIGITAL REFLECTION DENSITOMETERLocation and Description of Major Components - TM-5-3610-257-14_210TECHNICAL PRINCIPLES OF OPERATION - TM-5-3610-257-14_211Detailed. - TM-5-3610-257-14_212Detailed. - cont - TM-5-3610-257-14_213Detailed. - cont - TM-5-3610-257-14_214Section II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_215DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS - TM-5-3610-257-14_216OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_217Table 4-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_218Table 4-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - ContOPERATION UNDER USUAL CONDITIONS. - TM-5-3610-257-14_220Operating Procedures - TM-5-3610-257-14_221Section III. OPERATOR MAINTENANCE - TM-5-3610-257-14_222Table 4-2. TROUBLESHOOTING Section IV. ORGANIZATIONAL MAINTENANCE - TM-5-3610-257-14_224Table 4-3. ORGANIZATIONAL TROUBLESHOOTING - TM-5-3610-257-14_225Table 4-3. ORGANIZATIONAL TROUBLESHOOTING - TM-5-3610-257-14_226Table 4-3. ORGANIZATIONAL TROUBLESHOOTING - cont ORGANIZATIONAL MAINTENANCE PROCEDURES - TM-5-3610-257-14_228Remove/Install DensitometerReplace Probe Lamp.Replace Probe Lamp. - cont Replace Filter.Replace Filter. - cont Replace READ Pushbutton - TM-5-3610-257-14_234Replace READ Pushbutton - cont - TM-5-3610-257-14_235Replace POWER ON/OFF SwitchReplace Fuse Holder. - TM-5-3610-257-14_237Replace ZERO Control.Replace Transformer - TM-5-3610-257-14_239Replace Voltage Selection Switch - TM-5-3610-257-14_240Replace SLOPE ControlReplace Power Cord - TM-5-3610-257-14_242Replace Power Cord - cont - TM-5-3610-257-14_243Replace FOURTH-DIGIT ON/OFF Switch - TM-5-3610-257-14_244Replace CapacitorReplace ConnectorReplace Connector - cont Aline Reflection Probe Optical System - TM-5-3610-257-14_248Section V. DIRECT/GENERAL SUPPORT MAINTENANCE - TM-5-3610-257-14_249MAINTENANCE PROCEDURES - TM-5-3610-257-14_250Table 4-4. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - TM-5-3610-257-14_251Table 4-4. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - TM-5-3610-257-14_252Replace CHANNEL Control Switch - TM-5-3610-257-14_253Replace CHANNEL Control Switch - cont - TM-5-3610-257-14_254Replace Clock Board Assembly - TM-5-3610-257-14_255Replace Clock Board Assembly - cont - TM-5-3610-257-14_256Replace Logic Board Assembly - TM-5-3610-257-14_257Replace Logic Board Assembly - cont - TM-5-3610-257-14_258Replace Logic Board Assembly - cont - TM-5-3610-257-14_259Replace Power Supply Board Assembly - TM-5-3610-257-14_260Replace Display Board AssemblyReplace Display Board Assembly - cont Replace Photomultiplier Board/TubeReplace Photomultiplier Board/Tube - cont SLOPE, FRONT PANEL ZERO, FRONT PANEL SCHEMATIC DIAGRAM - TM-5-3610-257-14_266SCHEMATIC DIAGRAM - TM-5-3610-257-14_267SCHEMATIC DIAGRAM - TM-5-3610-257-14_268SCHEMATIC DIAGRAM - TM-5-3610-257-14_269SCHEMATIC DIAGRAM - TM-5-3610-257-14_270CHAPTER 5 PHOTOGRAPHIC PROCESSING SINKLocation and Description of Major Components - TM-5-3610-257-14_273Equipment Data - TM-5-3610-257-14_274Refrigeration SystemHeating SystemElectrical System - TM-5-3610-257-14_277Section II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_278OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_279PMCS Procedures - TM-5-3610-257-14_280Table 5-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_281Table 5-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES- Cont - TM-5-3610-257-14_282Table 5-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES- Cont - TM-5-3610-257-14_283Table 5-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES- Cont - TM-5-3610-257-14_284Table 5-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES- Cont - TM-5-3610-257-14_285Table 5-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES- Cont - TM-5-3610-257-14_286OPERATION UNDER USUAL CONDITIONS - TM-5-3610-257-14_287OPERATION UNDER UNUSUAL CONDITIONS - TM-5-3610-257-14_288Table 5-2. TROUBLESHOOTING - TM-5-3610-257-14_289Table 5-2. TROUBLESHOOTING - Cont - TM-5-3610-257-14_290OPERATORS MAINTENANCE PROCEDURES.Adjust Cabinet Thermostat.Section IV. ORGANIZATIONAL MAINTENANCE - TM-5-3610-257-14_293Table 5-3. ORGANIZATIONAL TROUBLESHOOTINGTable 5-3. ORGANIZATIONAL TROUBLESHOOTING - ContMAINTENANCE PROCEDURES. - TM-5-3610-257-14_296Adjust Sink Thermostat (Calibrate)Adjust Sink Thermostat (Calibrate) - cont - TM-5-3610-257-14_298Adjust Sink Thermostat (Calibrate) - cont - TM-5-3610-257-14_299Replace Sink Thermostat.Replace Sink Thermostat. - cont - TM-5-3610-257-14_301Replace Sink Thermostat. - cont - TM-5-3610-257-14_302Replace Cabinet Thermostat.Replace Cabinet Thermostat. - cont Repair Recirculating Water PumpRepair Recirculating Water Pump - cont Replace Recirculating Water PumpReplace Faucet Pump.Replace SwitchReplace Condenser Fan Motor.Replace Auxiliary FanReplace Heating ElementReplace Photographic Processing SinkReplace Photographic Processing Sink - cont Replace Water Storage TankReplace Water Storage Tank - cont Section V. DIRECT/GENERAL SUPPORT MAINTENANCE - TM-5-3610-257-14_317Table 5-4. DIRECT/GENERAL SUPPORT TROUBLESHOOTINGTable 5-4. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - ContINDEX - TM-5-3610-257-14_320Replace Compressor Assembly.Replace Thermostatic Expansion ValveReplace Thermostatic Expansion Valve - cont Replace Remote Reading ThermometerReplace Remote Reading Thermometer - cont Replace Water Level Gage.Replace Immersion Heater.Replace Immersion Heater - cont Replace Magnetic ContactorReplace Magnetic Contactor - cont - TM-5-3610-257-14_330Replace Magnetic Contactor - cont - TM-5-3610-257-14_331CHAPTER 6 FILM DRYERLocation and Description of Major Components - TM-5-3610-257-14_333Equipment Data. - TM-5-3610-257-14_334Electrical System - TM-5-3610-257-14_335Section II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_336OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES. - TM-5-3610-257-14_337PMCS Procedures - TM-5-3610-257-14_338Table 6-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_339Table 6-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_340Table 6-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_341OPERATION UNDER USUAL CONDITIONS. - TM-5-3610-257-14_342Table 6-2. TROUBLESHOOTING - TM-5-3610-257-14_343Replace Fuse. - TM-5-3610-257-14_344Replace Filter - TM-5-3610-257-14_345Section IV. ORGANIZATIONAL MAINTENANCE - TM-5-3610-257-14_346List of tools and materials required for PMCS Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_348Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_349Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_350Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_351Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_352Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_353Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_354Table 6-4. ORGANIZATIONAL TROUBLESHOOTING - TM-5-3610-257-14_355Table 6-4. ORGANIZATIONAL TROUBLESHOOTING - Cont - TM-5-3610-257-14_356Table 6-4. ORGANIZATIONAL TROUBLESHOOTING - Cont - TM-5-3610-257-14_357MAINTENANCE PROCEDURES. - TM-5-3610-257-14_358Replace ControlsReplace Controls - cont Replace Gear Motor and Gear CouplingReplace Gear Motor and Gear Coupling - cont Replace Air PumpsReplace Air Pumps - cont Replace Film DryerReplace Film Dryer - cont CHAPTER 7 LIGHT TABLE CABINET ASSEMBLYSection II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_368OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_369Table 7-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_370Table 7-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - ContOPERATION UNDER USUAL CONDITIONS - TM-5-3610-257-14_372Section III. OPERATOR MAINTENANCE - TM-5-3610-257-14_373Table 7-2. TROUBLESHOOTING - TM-5-3610-257-14_374Table 7-2. TROUBLESHOOTING - Cont - TM-5-3610-257-14_375Replace Fluorescent TubeReplace Fluorescent Tube - cont Replace Ceramic Condenser.Replace Ceramic Condenser. - cont Replace Glass - TM-5-3610-257-14_380Section IV. ORGANIZATIONAL MAINTENANCE - TM-5-3610-257-14_381Table 7-3. ORGANIZATIONAL TROUBLESHOOTING - TM-5-3610-257-14_382Replace Power Switch - TM-5-3610-257-14_383Replace Power Switch - cont - TM-5-3610-257-14_384Replace Ballast.Replace Ballast. - cont Replace Light Table Cabinet AssemblyCHAPTER 8 VIEWING STAND ASSEMBLYTECHNICAL PRINCIPLES OF OPERATION - TM-5-3610-257-14_391Section II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_392PMCS Procedures - TM-5-3610-257-14_393Table 8-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_394Table 8-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_395Table 8-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont - TM-5-3610-257-14_396Section III. OPERATOR MAINTENANCE - TM-5-3610-257-14_397Table 8-2. TROUBLESHOOTING SERVICE UPON RECEIPT. - TM-5-3610-257-14_399Table 8-3. ORGANIZATIONAL TROUBLESHOOTING - ContMAINTENANCE PROCEDURES - TM-5-3610-257-14_401Replace Film Clip.Replace Porcelain Socket(s).Replace Toggle SwitchReplace Fluorescent Light FixturePREPARATION FOR STORAGE OR SHIPMENT - TM-5-3610-257-14_406CHAPTER 9 FURNITURE AND CABINETS - TM-5-3610-257-14_408TECHNICAL PRINCIPLES OF OPERATION - TM-5-3610-257-14_409Section III. OPERATOR MAINTENANCEORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - TM-5-3610-257-14_411Replace Door Hinge (Piano Hinge) - TM-5-3610-257-14_412Replace Door Latch (Wall Storage Cabinet) - TM-5-3610-257-14_413Replace Door Latch (Wall Storage Cabinet) - cont Remove/Install Wall Storage Cabinet - TM-5-3610-257-14_415Replace Contact Screen Rack ChainReplace Contact Screen Rack Cupboard CatchRemove/Install Contact Screen RackReplace Strap and Buckle (Lamp Storage Rack)Replace Strap and Clip (Lamp Storage Rack).Remove/Install Lamp Storaqe RackReplace Developing Tray Cabinet LatchReplace Film Storaqe BoxReplace Target Storage Box.CHAPTER 10 SUPPORT ITEMS - TM-5-3610-257-14_426Section II. OPERATING INSTRUCTIONS - TM-5-3610-257-14_427Invar Bar.Beam CompassBeam Compass and Invar Bar Operating Procedure - TM-5-3610-257-14_430Beam Compass and Invar Bar Operating Procedure - TM-5-3610-257-14_431Beam Compass and Invar Bar Operating Procedure - cont Preparation for Movement. - TM-5-3610-257-14_433Section III. OPERATOR MAINTENANCE - TM-5-3610-257-14_434SERVICE UPON RECEIPT - TM-5-3610-257-14_435Replace Utility Pump BrushesAPPENDIX A REFERENCES - TM-5-3610-257-14_437APPENDIX A REFERENCES - cont - TM-5-3610-257-14_438APPENDIX B MAINTENANCE ALLOCATION CHART - TM-5-3610-257-14_439EXPLANATION OF COLUMNS IN THE MAC, SECTION II - TM-5-3610-257-14_440EXPLANATION OF COLUMNS IN THE MAC, SECTION II - cont - TM-5-3610-257-14_441EXPLANATION OF COLUMNS IN TOOL AND TEST EQUIPMENT REQUIREMENTS, SECTION III - TM-5-3610-257-14_442Section II. MAINTENANCE ALLOCATION CHART - TM-5-3610-257-14_443Section II. MAINTENANCE ALLOCATION CHART - TM-5-3610-257-14_444Section II. MAINTENANCE ALLOCATION CHART - TM-5-3610-257-14_445SECTION III. TOOL AND TEST EQUIPMENT REQUIREMENTS - TM-5-3610-257-14_446SECTION III. TOOL AND TEST EQUIPMENT REQUIREMENTS - TM-5-3610-257-14_447Section IV. REMARKS - TM-5-3610-257-14_448APPENDIX C COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS LISTS - TM-5-3610-257-14_449Section II. COMPONENTS OF END ITEM - TM-5-3610-257-14_450Section II. COMPONENTS OF END ITEM - TM-5-3610-257-14_451Section II. COMPONENTS OF END ITEM - TM-5-3610-257-14_452Section II. COMPONENTS OF END ITEM - TM-5-3610-257-14_453Section II. COMPONENTS OF END ITEM - TM-5-3610-257-14_454Section II. COMPONENTS OF END ITEM - TM-5-3610-257-14_455Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_456Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_457Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_458Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_459Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_460Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_461Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_462Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_463Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_464Section III. BASIC ISSUE ITEMS - TM-5-3610-257-14_465APPENDIX D ADDITIONAL AUTHORIZATION LIST - TM-5-3610-257-14_466APPENDIX E EXPENDABLE SUPPLIES AND MATERIALS LISTSection II. EXPENDABLE SUPPLIES AND MATERIALS LISTSection II. EXPENDABLE SUPPLIES AND MATERIALS LIST - Cont - TM-5-3610-257-14_469Section II. EXPENDABLE SUPPLIES AND MATERIALS LIST - Cont - TM-5-3610-257-14_470INDEX - TM-5-3610-257-14_471INDEX - Cont - TM-5-3610-257-14_472INDEX - Cont - TM-5-3610-257-14_473INDEX - Cont - TM-5-3610-257-14_474INDEX - Cont - TM-5-3610-257-14_475INDEX - Cont - TM-5-3610-257-14_476INDEX - Cont - TM-5-3610-257-14_477INDEX - Cont - TM-5-3610-257-14_478INDEX - Cont - TM-5-3610-257-14_479INDEX - Cont - TM-5-3610-257-14_480INDEX - Cont - TM-5-3610-257-14_481INDEX - Cont - TM-5-3610-257-14_482INDEX - Cont - TM-5-3610-257-14_483INDEX - Cont - TM-5-3610-257-14_484INDEX - Cont - TM-5-3610-257-14_485INDEX - Cont - TM-5-3610-257-14_486INDEX - Cont - TM-5-3610-257-14_487INDEX - Cont - TM-5-3610-257-14_488INDEX - Cont - TM-5-3610-257-14_489INDEX - Cont - TM-5-3610-257-14_490INDEX - Cont - TM-5-3610-257-14_491INDEX - Cont - TM-5-3610-257-14_492FO-1. Light Integrating Exposure Control Instrument SchematicFO-2. Camera Section Electrical Schematic