TB 1-4920-443-35
AEDATS II T700 Alignment Worksheet
(c) MT-15, 0-100 psig Fuel inlet pressure (Refer to pages 38 step 42)
1 Using the pressure calibrator, apply the following pressures to MT-15
Vertical Scale
Pressure
Actual
AEDATS 2
Vertical Scale
Top row 9
(psid)
Pressure
(PFI)
+/- 2 Psi
+/- 1 Psi
Vent
____________
____________
____________
20
____________
____________
____________
40
____________
____________
____________
60
____________
____________
____________
80
____________
____________
____________
100
____________
____________
____________
R-cal
____________
(d) MT-16, 0-50 psig, Dyno lube inlet pressure
(Refer to pages 38 step 42)
1 Using the pressure calibrator, apply the following pressures to MT-16 (PT408) and record the
results. NOTE: Calibrate 5 PS Alarm in conjunction with MT-16.
Vertical Scale
Pressure
Actual
AEDATS 2
Vertical Scale
bottom row 11
(psid)
Pressure
(pdyn_Sup)
+/- 2 Psi
+/- 1 Psi
Vent
____________
____________
____________
10
____________
____________
____________
20
____________
____________
____________
30
____________
____________
____________
40
____________
____________
____________
50
____________
____________
____________
R-cal
____________
(e) Fault light panel
(f) J BOX
1 T-700 dyno low oil press fwd _______ 5 PS set 10.5 psig on decreasing pressure. (+/-.5)
2 T-700 dyno low oil press aft _______ 6 PS set 10.5 psig on decreasing pressure. (+/-.5)
3 T-700 engine low oil pressure switch _______ 3PS set 25 psig on decreasing pressure. (+/-
2)
105