TM 5-6675-328-14
Table 7-3. BATTERY CHARGER OUTPUT VOLTAGE
Battery V
Output V
6
6.5 - 8.5
12
13 - 16.5
18
19 - 24
24
25 - 33
WARNING
Battery may explode and cause injury if charging rate is not reduced immediately when violent gassing
occurs or battery becomes uncomfortably hot to the touch.
NOTE
Steady gassing and warm battery indicates battery is approaching full charge.
(10)
TIMER will turn charger off when charging is completed. If TIMER is in HOLD position, charging is complete
when charging current approaches zero and battery is gassing freely.
(11)
When charging is completed, turn TIMER and CHARGING RATE switches to OFF.
(12)
Unplug ac power cord.
(13)
Disconnect charging cables.
(14)
Remove wet cloth from battery vent caps and tighten caps.
7-7.
OPERATION UNDER UNUSUAL CONDITIONS . This equipment is designed for operation only in a controlled
environment.