TM 5-6675-325-14
1-16.5
NOTE
Be sure wires are not kinked or strained.
j. Reinstall mounting screws.
k. Reinstall cover plate and secure with screws.
1.
Turn on switch circuit breaker.
Replace Blackout/Dome Light Microswitch.
MOS: 83FJ6, Reproduction Equipment Repairer
or
41B, Topographic Instrument Repair Specialist
TOOLS: Flat Tip Screwdriver
6 in. Adjustable Wrench
SUPPLIES:
Microswitch
Death or serious injury
off before servicing.
W A R N I NG
may occur from electrical shock unless power is
a.
Turn off blackout/dome light circuit breaker.
b. Remove conduit cover.
c.
Remove nut and pull out switch to expose wiring.
1-69