TM 5-6675-325-14
3-16.12 Adjust Cam Switch Actuator.
MOS: 41B, Topographic Instrument Repair Specialist
TOOLS: Cross Tip Screwdriver
Thickness Gage
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
a.
Unplug power cord.
b. Remove rear panel.
c.
Loosen switch mounting screws.
NOTE
Place feeler gage horizontally between cam lobes and switch actuators
so that it is between lobe and actuator on all three switches at same
time.
d. Place 0.007 in. (0.178 mm) thickness gage between switch actuators
and cam lobes.
e.
Adjust switch location so that all three actuators bottom out.
f. Tighten mounting screws.
g.
Reinstall rear panel.
h. Plug in power cord.
3-84