TM 5-6675-324-14
Pull fan from blower motor shaft.
g.
R e m o v e two retaining bolts and defective blower motor.
h.
I n s t a l l new blower motor and secure with two retaining bolts.
i.
P u s h blower fan onto blower motor shaft.
j.
k. Reinstall b l o w e r shroud and secure with three screws.
Reconnect b l o w e r supply leads to motor leads.
1.
Reinstall p r i n t e d c i r c u i t b o a r d .
m.
Reinstall i n t e r l o c k s w i t c h .
n.
Plug in power cord.
o.
Close top cover.
p.
4 - 1 6 . 1 0 Replace Drive Motor.
MOS :
Cross Tip Screwdriver (6 in.)
TOOLS:
Drive Motor
SUPPLIES:
WARNING
Death or serious injury may occur from electrical shock
unless
power
cord
is
unplugged before servicing the copy machine.
Unplug power cord.
a.
4-81