TM 5-6675-324-14
3-20.38 Adjust Secondary Corona Voltage.
MOS: 35E, Special Electronic Devices Repairer
Flat Tip Screwdriver (4 in.)
TOOLS :
Cross Tip Screwdriver (4 in.)
SUPPLIES: Copy Paper
WARNING
Electrical shock hazard. You must stand on rubber matting as a protective
measure before performing this procedure. Death or serious injury could
result.
a. Turn power switch to O (OFF).
b. Remove right side panel.
Insert cassette filled with paper.
c.
d. Turn power switch to 1 (ON).
Set exposure control lever to 5.
e.
f. Set copy number display via key strip to 5.
Press COPY START key when WAIT/STANDBY indicator stops flashing.
g.
3-227