TM 5-6675-324-14
NOTE
Be
sure
wires are not kinked or strained.
R e i n s t a l l mounting screws.
j.
k . Reinstall cover plate and secure with screws.
T u r n on switch circuit breaker.
l.
1-16.5 Replace Blackout/Dome Light Microswitch.
83FJ6, Reproduction Equipment Repairer
MOS :
41B, Topographic Instrument Repair Specialist
TOOLS:
Flat Tip Screwdriver
6 in. Adjustable Wrench
Microswitch
SUPPLIES:
Death or serious injury may occur from electrical shock unless power is
off before servicing.
a.
Turn off blackout/dome light circuit breaker.
b. Remove conduit cover.
Remove nut and pull out switch to expose wiring.
c.
1-69