Table 1-4. ORGANIZATIONAL TROUBLESHOOTING - C o n t
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FLUORESCENT CEILING LAMP IS INOPERATIVE - Cont
Step 3.
Check for shorts in RF Filter.
2.
(b) If continuity does not exist, replace switch (paragraph
1-16.4).
EMERGENCY LIGHTS ARE INOPERATIVE.
3.
Press in test indicator.
.If lamps do not light, replace emergency light assembly (paragraph
1-16.11).
NO POWER TO EQUIPMENT.
4.
Step 1.
Check circuit breaker ON/OFF position.
(a) If circuit breaker is ON, proceed to step 2.
(b) If circuit breaker is OFF, turn ON.
(c) If circuit breaker trips repeatedly, notify power supply
supervisor.
Check circuit breaker input for 120 V ac.
Step 2.
(a) If input voltage is present, proceed to step 3.
(b) If input voltage is not present, refer to direct/general
support maintenance for repair or replacement of defective
wiring.