WARNING
High voltages that are capable of causing death may be stored in CRT after
power is removed. Be sure CRT is discharged and reduced to zero volts.
d. Remove high-voltage screen by removing screws.
e.
To remove voltage from CRT, short anode to ground using insulated tool.
f. Disconnect CRT yoke connector, CRT base connector, high-voltage
connector and lens shelf plug.
g.
Remove bolt at each corner of lens shelf.
h. Remove entire assembly from cabinet.