TM 5-6675-319-14
CAUTION
Do not stop machine in midcycle to gain access to switch. Damage to ma-
c h i n e w i l l r e s u l t.
NOTE
Note position of connecting rod .
d.
e.
f .
g .
h.
i .
j .
k .
1.
m.
n.
Remove bolts and washers from connecting block, and slide connecting
rod as required to gain access to microswitch S202.
Remove screws and washers holding microswitch bracket.
Remove screws and washers holding microswitch in place.
Tag and disconnect microswitch wiring and remove defective switch.
Reconnect wiring and secure microswitch to mounting bracket.
Reinstall mounting bracket to frame.
Reposition connecting rod and secure to connecting block.
Adjust microswitch to close position by moving mounting bracket up or
down.
Reinstall side cover.
Turn on circuit breaker .
Turn on MASTER POWER switch.
9-137