TM 5-6675-319-14
Table 9-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
ROLL PAPER TRANSPORT FUSE F301 BLOWS AS SOON AS HOOD RISES, PREVENTING RPT
OPERATION. APL WORKS NORMALLY IN SINGLE-PRINT OPERATION - Cont
Step 3.
Check print counter CTR301 for continuity.
I f c o n t i n u i t y d o e s n o t e x i s t , r e p l a c e d e f e c t i v e p r i n t c o u n t er
(paragraph 9-16.2).
10.
RPT PAPER FEED ROLLERS DO NOT TURN
Check paper stop solenoid LS301 for continuity.
Replace defective paper stop solenoid LS301 (paragraph 9-16.3)
11.
REVOLUTION COUNTER DOES NOT COUNT DOWN.
Check revolution counter for continuity.
Replace defective repeat revolution counter (paragraph 9-16.6).
12. RPT PAPER DRIVE SYSTEM CONTINUES TO OPERATE UNTIL HOOD IS CLOSED.
Check relay RY301 for continuity.
Replace defective relay RY301 (paragraph 9-16.1).
9-83