TM 5-6675-319-14
i .
Rotate adjustment screw in opposite direction until switch clicks again.
NOTE
One full turn of adjustment screw represents approximately 12°F (7.2°C).
j. Set adjustment screw halfway between points where switch clicked.
k . R e i n s t a l l t h e r m o s t a t c o v e r .
NOTE
Be sure bulb gasket seats properly in bushing.
l .
Reinstall bulb and gasket in heat exchanger.
m.
R e i n s t a l l f r o n t c o v e r.
n .
R e f i l l s i n k w i t h w a t e r t o p r o p e r l e v e l .
o .
Plug in sink power cord.
3-16.2 Replace Sink Thermostat.
MOS: 83FJ6, Reproduction Equipment Repairer
PERSONNEL: Two persons are required to perform this procedure.
TOOLS: Cross Tip Screwdriver
Flat Tip Screwdriver
11/16 in. Combination Wrench
SUPPLIES: Sink Thermostat
WARNING
Death or serious injury may occur from electrical shock unless power
cord is unplugged before servicing.
a.
Unplug sink power cord.
b. Remove drain plug and drain water from sink.
c .
Remove front cover.
3-32