CAUTION
Use care when removing bulb to avoid damaging sensing tub.
g .
Loosen
h. Remove
TM 5-6675-319-14
nut and remove sensing bulb.
mounting screws and housing screw. Remove thermostate.
i .
Install new thermostat with mounting screws and housing screw.
j .
R e i n s t a ll
r e t a i n i n g
k . R e c o n n e ct
l .
Reconnect
m.
R e i n s t a l l
thermostat sensing bulb connector in tank and tighten
n u t.
cable and cable connector to box and secure with nut.
t h e r m o s t a t w i r i n g.
front cover and secure with screws.
CAUTION
Do not turn on circuit breaker or heater switch until tank is refilled or
heating element will be damaged.
n.
F i l l t a n k w i t h w a t e r.
o.
Turn on circuit breaker.
2-119