TM 5-6675-317-14
2-16.3
k.
Solder black lead to fuse holder.
l.
Reinstall wire clamps.
m.
Reinstall switch plate and secure with socket head screws.
n. Plug in power cord.
Replace Receptacle.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS:
Flat Tip Screwdriver
5/64 in. Hex Head Key Wrench
SUPPLIES: Receptacle
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
a.
Turn off power switch.
b.
Unplug power cord.
c.
Remove socket head screws and pull switch plate out.
2-22