TM 5-6675-316-14
NOTE
The following additional step is required when replacing override thermostat.
i.
Remove resistor from override thermostat. Attach to new thermostat.
j.
Remove defective thermostat.
k.
Insert new thermostat in wax coater in same manner as original.
l.
Tighten mounting nut.
m.
Reconnect
n.
Reinstall
o.
Reinstall
wires according to wiring diagram.
inner panel.
top deck cover and top roller cover.
8-68