TM 5-6675-315-14
Table 2-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. CUTTER MECHANISM RUNS FORWARD BUT RAM DOES NOT MOVE.
Step 1. Check for air leaks in gear pump pipe connectors.
(a)
If no leaks are present, proceed to step 2.
(b)
Tighten pipe connections.
(c)
Replace o-ring
Step 2. Check for sticking solenoid valve.
(a)
If valve operates freely, proceed to step 3.
(b)
Replace solenoid valve (paragraph 2-20.4).
Step 3. Check for defective solenoid valve coil.
(a)
If coil is good, proceed to step 4.
(b)
Replace solenoid valve (paragraph 2-20.4).
Step 4. Check for defective pump motor.
Replace pump motor (paragraph 2-20.6).
4.
CYCLE STOP (KLP) LIGHTS BUT BALE CHAMBERS ARE ONLY PARTIALLY FILLED.
Check for proper operation of pressure activated switch DW.
If out of adjustment, replace switch (paragraph 2-20.5).