TM 5-3610-285-14
WARNING
Death or serious injury may occur from electrical shock failure to turn off and padlock safety
switch before repairing molding.
NOTE
Alternate lighting is required to perform this task.
a. Turn off and padlock safety switch.
b. Remove conduit cover.
c. Inspect wires for damage.
NOTE
Refer to direct support maintenance for wiring repair if necessary.
d. Loosen wiring and carefully pull it from the entire base section.
e. Remove screws and base from wall.
f. Mark and measure damaged area on molding. Record measurement.
g. Cut damaged area from molding.
h. Cut section from new molding to the length recorded in step f.
i. Using damaged area as a template, mark mounting holes on new piece.
j. With a number 25 drill bit, drill holes in new molding.