TM 5-3610-285-14
Table 1-2. OPERATOR'S TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. BLACKOUT SWITCH DOES NOT OPERATE.
Step 1.
Check blackout switch position.
(a)
If switch is ON, proceed to step 2.
(b)
If switch is OFF, reset switch to BLACKOUT.
Step 2.
Check to see that striker plate contacts roller on microswitch.
(a)
Loosen screws and move plate up or down until microswitch operates.
(b)
If blackout switch still fails to operate, refer to organizational maintenance.
1-10. OPERATOR'S MAINTENANCE PROCEDURES.
a. This section contains instructions covering operator maintenance functions for the Photomechanical Section.
Personnel required are listed only if the task requires more than one.
b. After completing each maintenance procedure, perform operational check to be sure that equipment is properly
functioning.
1-46