h.
Cut wire ties. Remove cable from retaining clips and move cable out of way of blower assembly.
i.
Remove mounting bolts, lockwashers, and flat washers securing blower motor base to processor frame.
j.
Remove two screws and bracket securing fixer recirculation pump assembly to processor frame. Move pump
assembly aside.
k.
Remove drive motor power cable from retaining clips on side of blower shroud.
l.
Slowly withdraw blower assembly from left side of processor. Remove isolator pads.
m.
Remove TRANSPORT SPEED control knob.
n.
Remove screws and front control panel.
5-165