TM 5-3610-285-14
Table 5-5. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
BLOWER DOES NOT BLOW AIR WHEN MAIN DRIVE AND DRYER SWITCHES ARE ON, AND STANDBY
FEATURE IS NOT ON - Cont
WARNING
Death or serious injury may occur from electrical shock unless power is turned off before servicing.
Step 1. Check for defective fuse FU4.
(a)
If fuse is good, proceed to step 2.
(b)
If fuse is defective, replace fuse (paragraph 5-16.1).
Step 2. Check for defective fuse FU5.
(a)
If fuse is good, proceed to step 3.
(b)
If fuse is defective, replace fuse (paragraph 5-16.1).
5-104