c.
Tag and disconnect vacuum hoses from vacuum pumps.
NOTE
If the rear vacuum pump is to be replaced, the front pump must be removed first.
d.
Remove mounting bolts for vacuum pump(s) and remove defective vacuum pump from inside housing.
e.
Remove electrical cover plate.
f.
Tag and disconnect wires from defective vacuum pump.
g.
Reconnect wires to new vacuum pump.
h.
Reinstall cover plate over electrical connections.
i.
Insert new vacuum pump into flip-top platemaker housing.
j.
Reinstall mounting bolts for vacuum pump(s).
k.
Reconnect vacuum hoses to vacuum pump(s).
l.
Reinstall lower cabinet panel.
m.
Turn on power panel circuit breaker.
2-63