TB 1-4920-443-35
AEDATS IV T64 ALIGNMENT WORKSHEET
(9) Hydraulic Pressures (T64)
(Refer to page 44 step 43) High Pressure Calibrator
(a) MT-10 0-1500 psig fuel manifold Pressure
1 Using the pressure calibrator, apply the following pressures to MT-10, and record the results.
Vertical Scale top row 10
5SE01313-9
Actual
AEDATS 4
6SE00950-8
Pressure
Pressure
(PFD)
Vertical Scale
(psig)
psi
+/- 2 psi
+/- 2 psi
Vent
____________
____________ ____________
300
____________
____________ ____________
600
____________
____________ ____________
900
____________
____________ ____________
1200
____________
____________ ____________
1500
____________
____________ ____________
R-cal
____________
Transducer: T31 Hardware Name: HL10
(b) MT-5 0-200 psig Engine Lube Discharge
1 Using the pressure calibrator, apply the following pressures to MT-5, and record the results.
NOTE: Calibrate 15 PS Alarm in conjunction with MT-5.
Vertical Scale top row 7
5SE01313-7
Actual
AEDATS 4
6SE00950-4
Pressure
Pressure
(PELD)
Vertical Scale
(psig)
psi
+/- 1 psi
+/- 2 psi
Vent
____________
____________ ____________
40
____________
____________ ____________
80
____________
____________ ____________
120
____________
____________ ____________
160
____________
____________ ____________
200
____________
____________ ____________
R-cal
____________
Transducer: T25 Hardware Name: HL05
(c) MT-8 -15 to -5 psig PT Sump Pressure
1 Using the Low pressure calibrator, apply the following pressures to MT-8, and record the
results.
Vertical Scale top row 8
5SE01313-7
Actual
AEDATS 4
6SE00950-10
Pressure
Pressure
(PSUMP PT)
Vertical Scale
(psig)
psi
+/- 1 psi
+/- 2 psi
-15
____________ ____________ ____________
-10
____________ ____________ ____________
-5
____________ ____________ ____________
Vent
____________ ____________ ____________
+5
____________ ____________ ____________
R-cal
____________
Transducer: T29 Hardware Name: HL08
203